The BKD 150 system from UGA
Sealing cables in the blink of an eye
The bayonet mount of the BKD 150 system enables the quick connection of system covers or cable protection pipes to the wall inserts. And a reliable seal is already guaranteed. Sealing cables doesn't get any easier. Thermal shrink sleeves TM are supplied with the system covers as standard. Optionally, cold shrink sleeves KS are also available.
NEW! Our modified system cover BKD150-D3/59-FHE60/400-TM

Downloads & Information
Practical examples & product pictures
Our products at a glance
Double wall insert BKD150
Double wall insert suitable for connecting a system cover or KSS system on both sides.
Can be used from 100mm wall thickness.
Application: | Waterproof concrete stress class 1 and 2. | |
Advantages: |
|
|
Tightness: | Gas- and watertight up to 2,5 bar | |
Product text: |
BKD150-K2/(L) | (L) = wall thickness in mm |
Download:
Single wall insert BKD150
Single wall insert suitable for one-sided connection of a system cover or KSS system. Can be used from 50 mm wall thickness.
The direction of installation must be specified!
Application: | Waterproof concrete stress class 1 and 2. | |
Advantages: |
|
|
Tightness: | Gas- and watertight up to 2,5 bar | |
Product text: | BKD150-K/(L) | (L) = wall thickness in mm |
Download:
Angular wall insert BKD150
Application: | Waterproof concrete stress class 1 and 2. | |
Advantages: |
|
|
Tightness: | Gas- and watertight up to 2,5 bar |
Variants
Angular single wall insert
|
Angle for both variants |
Variants
Angular double wall insert
|
BKD150-K-S30/(L) | 30° | BKD150-K2-S30/(L) |
BKD150-K-S45/(L) | 45° | BKD150-K2-S45/(L) |
BKD150-K-S60/(L) | 60° | BKD150-K2-S60/(L) |
Download:
Bayonet system cover with collar BKD150-D-MA
Area of application: | In existing wall insert BKD 150 or BKD 150 assembly flange. | |
Advantages: |
|
|
Tightness | Gas- and watertight up to 0,5 bar |
(L) = wall thickness in mm
Prodct text | Clamping rage | Connection of KSS tube |
BKD150-D-MA75-89 | 75 - 89 mm | KSS-S 80 |
BKD150-D-MA100-110 | 100 - 110 mm | - |
BKD150-D-MA115-125 | 115 - 125 mm | KSS-S 110 |
BKD150-D-MA130-140 | 130 - 145 mm | KSS-S 125 |
BKD150-D-MA150-160 | 150 - 160 mm | - |
BKD150-D-MA160-170 | 160 - 170 mm | KSS-S 150 |
Download:
Bayonet system cover BKD150
Bayonet system cover BKD 150 with plastic connection pieces for quick and easy sealing. With five variants, UGA offers a solution for many applications on the construction site. The double safety through bayonet locking and additional screw connection makes this system cover one of the safest sealing systems available on the market.
Application: | In existing wall insert BKD 150 or BKD 150 assembly flange. |
Advantages: |
|
Tightness: | Gas -watertight up to 2,5 bar |
Variants | For cables or pipes with Ø (mm) | Description |
BKD150-D-1/80-TM | 26 - 78 | With one connection piece and one thermal shrink sleeve |
BKD150-D-1/110-TM | 36 - 108 | With one connection piece and one thermal shrink sleeve |
BKD150-D-3/59(3/3)-TM | 22 - 57 | With three connections pieces and three thermal shrink sleeves |
BKD150-D-7/38(7/7)-TM | 7 - 37 |
With seven connection pieces and six thermal shrink sleeves (one connection piece is
supplied closed, this can be openend if necessary)
|
BKD150-D-8/35(4/2)/25(4/2)-TM | 7 - 24 / 7 - 34 |
With four 35mm diameter connection pieces and two thermal shrink sleeves, as well
as four 25mm diameter connection pieces and two thermal shrink sleeves (four
connection pieces are supplied closed, they can be openend if necessary)
|
Download:
Accessories
Cable cleaner KR in 1 litre container, for environmentally friendly cleaning of cables of all kinds.
Order-No. KR
Bayonet system cover BKD150
Bayonet system cover BKD 150, closed
Blind cover for unoccupied wall inserts.
This system cover is included in the scope of delivery of each wall insert.
Application: In existing wall insert BKD 150 or BKD 150 assembly flange.
Order-No. BKD150-D
Download:
Assembly flange BKD150
Bayonet assembly flange, suitable for sealing of a core drilling in a wall or ceiling.
Supplied with flange sealing, sealing ring, protective cover anf fastening elements, optionally in galvanized steel or A4 stainless steel.
Suitable for one-sided connection of a system cover or KSS system; core drilling diameter maximum 150 mm; flange size 235 x 235 mm.
Area of application: Waterproof concrete stress classes 1 and 2.
Version |
Materials (fastening elements) |
BKD150-AF-235/BE-A4 |
Stainless steel A4 |
BKD150-AF-235/BE-VZ |
Galvanized steel |
Stainless steel double wall insert BKD150
Stainless steel double wall insert, suitable for sealing in accordance with DIN 18533 (fixed/loose flange design for black trough). Double-sided connection of a system cover or KSS system possible. Also available assembled in a battery (flange plate). Minimum wall thickness 100 mm.
Also available as stainless steel single wall insert. Minimum wall thickness 50 mm.
(L) = Wall thickness in mm
Variants | Flange diameter |
Seals against |
BKD150-K2-F+L-W2/(L)/V2A | 525 mm | pressurised water |
BKD150-K2-F+L-W1/(L)/V2A | 325 mm | non-pressurised water |
Download:
Single wall insert with pipe connection sleeve BKD150
Single wall insert with pipe connection sleeve, suitable for one-sided connection of a system cover or KSS system. Opposite side for the direct connection of a smooth-walled cable protection pipe with 110, 125 or 160 mm outside diameter. Minimum wall thickness 200 mm
Application: | Waterproof concrete stress class 1 and 2. | |
Advantages: |
|
|
Tightness: | Gas- and watertight up to 0,5 bar |
Variants | L = Wall thickness |
BKD150-K-SM110/(L) | 200-500 mm |
BKD150-K-SM125/(L) | 200-500 mm |
BKD150-K-SM160/(L) | 200-500 mm |
Also available as a single wall insert with a pipe connection adhesive sleeve.
Variants | L = Wall thickness |
BKD150-K-KM110/(L) | 200-500 mm |
BKD150-K-KM125/(L) | 200-500 mm |
BKD150-K-KM126/(L) | 200-500 mm |
BKD150-K-KM160/(L) | 200-500 mm |
Download:
Single wall insert with pipe connection sleeve in collar technology BKD150
Single wall insert with pipe connection sleeve in collar technology, suitable for one-sided connection of a system cover or KSS system. Opposite side for direct connection of a corrugated or smooth-walled cable protection pipe with 110 to 160 mm outside diameter. Minimum wall thickness 200 mm.
Application: | Waterproof concrete stress class 1 and 2. | |
Advantages: |
|
|
Tightness: | Gas- and watertight up to 0,5 bar |
Variants | clamping range in mm | L = wall thickness (Special lengths on request) |
BKD150-K-MA125/(L) | 110 - 125 | 200-500 mm |
BKD150-K-MA145/(L) | 130 - 145 | 200-500 mm |
BKD150-K-MA170/(L) | 160 - 170 | 200-500 mm |
Download:
Bayonet system cover BKD150-D-3/59(3/3)-FHE60/400-TM
Application: | Waterproof concrete stress class 1 and 2. |
Advantages: |
|
Tightness: | Gas- and watertight |
Product text: |
BKD150-D-3/59(3/3)-FHE60/400-TM |
System insert BKD150-E-WE/ZxD
The bayonet system insert can be mounted regardless of the subsequent fitting. Depending on how the cable or pipe is fitted, a corresponding exchangeable insert is used. A change of fitting is possible at any time by replacing the exchangeable insert.
Application: | In existing wall insert BKD 150 or BKD 150 assembly flange. | |
Advantages: |
|
|
Tightness: | Gas- and watertight up to 2 bar | |
Product text: | BKD150-E-WE/V2A/EPDM (Z)x(D) |
(Z) = Number of cables/pipes
(D) = Diameter of cables/pipes
|
System insert BKD150-E-ZS
With the BKD150-ZS system insert, cables or pipes with different diameters can be flexibly sealed. The cable diameters are infinitely variable thanks to the proven multilayer insert technology. Simply remove as many rubber elements as necessary until the desired diameter is reached. If you do not want to use a drilled hole or a core drilling, simply leave the rubber parts in the seal.
The system inserts with multilayers from UGA are suitable for universal use.
Application: | In existing wall insert BKD 150 or BKD 150 assembly flange. |
Advantages: |
|
Tightness: | Gas- and watertight up to 2 bar |
Multilayer inserts: Number of inserts x (diameter)
Variants | Multilayer inserts |
Drawing |
BKD150-E-ZS/V2A/EPDM 3x(22-54) |
3x(22-54) | BKD150-E-ZS_3x(22-54).pdf |
BKD150-E-ZS/V2A/EPDM 6x(4-32) |
6x(4-32) | |
BKD150-E-ZS/V2A/EPDM 9x(4-20) |
9x(4-20) | |
BKD150-E-ZS/V2A/EPDM 4x(4-32)+6x(4-20) |
4x(4-32)+6x(4-20) |
Accessories
Articulated spanner GSS
For the assembly of all system covers and KSS systems.
With adjustable leg
Order-No. GSS
Download:
Accessories
Cold welding tape with very good adhesive properties for sealing and for corrosion protection. Ideal for wrapping around cables and pipes to enlarge the diameter for shrinking. Suitable for all plastics and metals.
Download: