Fire protection for you
Fire protection is an essential part of construction projects. It is important to offer solutions for various challenges. With our broad product portfolio and the consulting from our fire protection experts, we can offer you a package that effectively covers the requirements for you regarding fire protection. As a sales partner of leading manufacturers, we can supply a comprehensive system package through our range of business connections.

Practical examples & product pictures
Our products at a glance
PYRO-SAFE FLAMMOPLAST KS
PYRO-SAFE FLAMMOPLAST KS 1 or 3 intumescent fire protection coatings
Colour: white
Quantity: 12.5 kg bucket
Variants | Properties | Mounting |
PYRO-SAFE FLAMMOPLAST KS 1 | Intumescent fire protection coating | painting, rolling or airless painting |
PYRO-SAFE FLAMMOPLAST KS 3 | Intumescent fire protection coating | filling |
PYRO-SAFE FLAMMOPLASTKS 1-W | Intumescent fire protection coating on wood |
Mineral wool
Mineral wool, bag a 10kg
Building material class A (DIN 4102), proof of usability: EN 14303
Fire behaviour class A1, melting point > 1000 °C
For the fire protection technical stuffing of joints and gaps in cable, pipe and combination bulkheads.
The mineral fibre made of rock wool is used for the fire protection technical stuffing of cavities and slits in cable, pipe and combination seals.
Combination bulkheads and joints in walls and ceilings.
Lamella mat "KLIMAROCK"
Lamella mat "KLIMAROCK", fire protection sectional insulation
roll 6100 x 500 mm = 3,05 m²
For the sheathing of non-combustible pipelines as fire protection sectional insulation in pipes and tubes and
Combination bulkheads in walls and ceilings.
Fire protection fabric
PYRO-SAFE DG-CR -LS Fire protection bandage, 10 m
100 mm wide / 10 running metres per roll
Fire protection fabric for use as a pipe wrap for flammable pipes.
Fire protection fabric
Fire protection fabric for use as cable bandage indoors and outdoors.
Width 110 cm, roll à 20 m (22m²)
Variants |
PYRO-SAFE KS1-CR |
PYRO-SAFE DG-CR 0,7 |
Fire protection silicone
Fire protection silicone in grey and white 310 ml cartridge.
Preventive fire protection, elastic and pressure-tight sealing of non-combustible
Pipes in wall and ceiling penetrations as well as flexible sealing of structural joints in the
Indoor and outdoor.
Fire protection acrylate
Fire protection acrylate in grey 310 ml cartridge
Flexible fire protection sealing of component joints in interior and exterior areas and
for sealing connections and joints with moderate elongation stress and without
constant exposure to moisture: e.g. between concrete, masonry, plaster surfaces, fibre cement,
Plasterboard, raw and anodised aluminium, wood or hard PVC.
Grouting cord
Fire protection gaskets in ceilings and load-bearing and non-load-bearing solid walls for
movement joints between components with similar load and deformation and for joints between
Shear load components, which are used as step joints (multi-stage joints) and as linear butt joints
(single-stage joints) can be formed.
Variants | Diameter | Length |
Grouting cord RP 55 / SG 300 - Ø 12 mm, roll à 100 m bags á 300 lfm |
12 mm | 100 m |
Grouting cord RP 55 / SG 300 - Ø 15 mm, roll à 100 m bags á 300 lfm |
15 mm | 100 m |
Grouting cord RP 55 / SG 300 - Ø 20 mm, roll à 20 m bags á 100 lfm |
20 mm | 20 m |
Grouting cord RP 55 / SG 300 - Ø 30 mm, roll à 20 m bags á 100 lfm |
30 mm | 20 m |
Grouting cord RP 55 / SG 300 - Ø 40 mm, roll à 20 m bags á 40 lfm |
40 mm | 20 m |
Grouting cord RP 55 / SG 300 - Ø 50 mm, roll à 20 m bags á 40 lfm |
50 mm | 20 m |
Grouting cord RP 55 / SG 300 - Ø 60 mm, roll à 20 m bags á 40 lfm |
60 mm |
20 m |
PYRO-SAFE BIOBAG
PYRO-SAFE BIOBAG Size 0, 1, 2
Universally and variably reusable fire protection cushions for fire protection technology
Closure of component openings and as temporary or definitive approved by the building authorities
Cable insulation in walls and ceilings.
Variants | Dimensions |
PYRO-SAFE BIOBAG Size 0 | 150 x 200 x 40 mm |
PYRO-SAFE BIOBAG Size 1 | 300 x 200 x 40 mm |
PYRO-SAFE BIOBAG Size 2 | 300 x 200 x 100 mm |
Mineral fibre boards
Mineral fibre boards 1 or 2 sides pre-coated with cardboard á 4 pcs.
Pre-coated mineral fibre boards serve as system boards for cable, pipe and combination bulkheads approved by the building authorities.
Dimensions: 1000 x 600 x D mm
Variants | D = thickness in mm | Coating |
Mineral fibre boards 50 | 50 | 1-sided |
Mineral fibre boards 60 | 60 | 1-sided |
Mineral fibre boards 60 | 60 | 2-sided |
Mineral fibre boards 50 KS1 | 50 | 1-sided |
Mineral fibre boards 60 KS1 | 60 | 1-sided |
Mineral fibre boards 60 KS1 | 60 | 2-sided |
Mineral fibre boards 80 KS1 | 80 | 2-sided |
PYRO-SAFE FLAMMOPLAST A
Colour: white
Quantity: 12.5 kg bucket
The endothermic, weather-resistant fire protection coating is particularly suitable for
for sealing large openings and joints and applying very thick layers.
Fire protetcion bandage BBR Pro
BBR Pro fire protection bandage for combustible pipes with/without Sk insulation.
Trades: drinking water, heating, cooling
Proof of usability: Z-19.17-2250
Scope of delivery: 10 wrapping tape 125 mm wide; incl. 10 fire protection signs, fixing wire and installation instructions.
For sealing off pipelines: PVC, PP, PE, PB, PE-X, ABS, ASA Ø ≤ 110 mm Plastic multilayer pipes with aluminium insert Ø ≤ 110 mm
Fire protetcion bandage ISO Pro
ISO Pro fire protection bandage for non-combustible pipes with insulation.
Trades: rainwater, drinking water, heating, refrigeration
Proof of usability: P-2401-267-16-MPA BS
Scope of delivery: 10 wrapping tape 125 mm wide; incl. 10 fire protection signs, fixing wire and installation instructions.
For sealing off pipelines: Steel, stainless steel, cast iron Ø ≤ 813.0 mm (in ceiling Ø ≤ 326.0 mm) Copper Ø ≤ 88.9 mm
ZZ fire protection plug
S30/S60/S90 combination penetration seal for solid walls, solid ceilings and light partition walls, and walls of the PRIOWALL type. Temporary as well as permanent fire protection of electrical cables and lines of all types and diameters, as well as non-combustible pipes
ZZ fire protection plug | max. Opening size in mm |
ZZ-fire protection plug BDS type 65 | 65 mm |
ZZ-fire protection plug BDS type 78 | 78 mm |
ZZ-fire protection plug BDS type 107 | 107 mm |
ZZ-fire protection plug BDS type 122 | 122 mm |
ZZ-fire protection plug BDS type 134 | 134 mm |
ZZ-fire protection plug BDS type 165 | 165 mm |
ZZ-fire protection plug BDS type 200 | 200 mm |
ZZ-fire protection plug BDS type 250 | 250 mm |
EN ZZ-DoBo BDS-N
Cable insulation S30/S60/S90 for solid walls, solid ceilings and light partition walls. Temporary as well as permanent fire protection of electrical cables and lines of all types and diameters
- Small bulkheads with a 75 or 100 mm diameter,
- cable with small to medium diameter,
- ducts in light partition walls,
- Bulkheads with a frequently changing occupancy
ZZ-DoBo BDS
|
Length (mm)
|
Version 1
|
100
|
Version 2
|
100
|
Version 3
|
150
|
Version 4
|
150
|
Fire protection collar FS-M R1
Our fire protection collar FS-M R1 can be used for a variety of combustible pipes.
Product advantages:
- for solid walls and ceilings,
- Dry construction walls and wooden beam ceiling
- with 2 x 45° bends, over socket, CV-connectors and
- electrofusion couplings
- at zero distance to equal and further bulkheads(supply and ventilation bulkheads)
Fire protection collar FS-M R2
Our fire protection collar FS-M R2 can be used for a variety of combustible pipes.
Product advantages:
- for solid walls and ceilings,
Dry construction walls and wooden beam ceilings *NEW* - with 2 x 45° bends, over socket, CV-connectors and
electrofusion couplings - at zero distance to equal and further bulkheads
(supply and ventilation bulkheads)
Available cuff dimensions FS-M R2 (mm): 32 - 160
ZZ fire protection foam 2K NE
Combined or cable insulation sealing up to EI 120 for solid walls, solid ceilings and light partition walls. Fire protection sealing for electrical cables, telecommunication cables, optical fibre cables, electrical installation pipes and combustible and non-combustible pipes.
- Quick and easy closing of building component openings
- Highly occupied bulkheads
- Difficult to access and irregular openings
Effective support measure ZZ W20
Purpose of an effective support
If cable systems are arranged vertically (ascending routes), effective support of the cables at a distance a of < 3.5 m is required to classify the functional integrity in accordance with DIN 4102-12 Para. 8.3. The aim of the effective support is the fireproof fastening of the cable system. This prevents the cable fastenings from failing due to the effects of fire. Due to the failure of the cable fastenings, the dead weight of the cables can no longer be transferred to the component, which can lead to the cables being torn off due to their dead weight.
ZZ fire protection box
Cable insulation S30/S60/S90 for solid walls, solid ceilings and light partition walls. Temporary as well as permanent fire protection of electrical cables and lines of all types and diameters.
- Medium and large bulkheads with a medium to high occupancy,
- cables of all types and diameters,
- Ducts in lightweight partition walls (frames made of non-combustible building panels are additionally omitted),
- Bulkheads with a frequently changing occupancy
ZZ fire protection brick 170 BDS-N
Combination penetration seal S30/S60/S90 for solid walls, solid ceilings and light partition walls. Temporary and permanent fire protection of electrical cables and lines of all types and diameters as well as combustible and non-combustible pipes.
- Medium and large bulkheads with a medium to high occupancy,
- Mixed assignments of cables and non-combustible pipes,
- Bulkheads with a frequently changing occupancy
ZZ fire protection brick 200 BDS-N
S90 combination bulkhead for solid walls, solid ceilings, light partition walls, plaster walls and walls of the PRIOWALL type. Temporary and permanent fire protection of electrical cables and lines of all types and diameters as well as combustible and non-combustible pipes.
- Medium and large bulkheads with a medium to high occupancy,
- Mixed assignments of cables, combustible and non-combustible pipes,
- pipes with rubber insulation,
- hydraulic lines and multi-layer composite pipes,
- Bulkheads with a frequently changing occupancy