Roof entries
Multi gabled roof entry, Multi flat roof entry

Downloads & Information
Practical examples & product pictures
Our products at a glance
Flat roof entry FDD-KF
Variants | Inside diameter | Stand height |
FDD100-KF | 100 mm | 410 mm |
FDD160-KF | 160 mm | 475 mm |
Flat roof entry FDD-FF
FDD with foil flange.
Flat roof entry FDD-FF, thermally insulated, non-flammable (A1), DN 100 or DN 160 with foil flange*, height 410 mm (DN100) or 475 mm (DN160)
*Foil flange versions:
PIB Rhepanol, EVA-VAEPlan, PVC Rhenofol, FPO Flagon, EVA Evalon, FPO Thermoplan, PVC Sikaplan, FPO Sarnafil, EPDM Novoproof
Variants | Inside diameter | Stand height |
FDD100-FF | 100 mm | 410 mm |
FDD160-FF | 160 mm | 475 mm |
Flat roof entry insulating roof elements FDD-IDE
Flat roof entry FDD-IDE, insulating roof element, thermally insulated, non-flammable (A1),
DN 100 for max. insulation thickness 200 / 300 / 400 mm, can be shortened individually to 80 mm.
Variants | max. insulation thickness |
FDD100-IDE/200 | 200 mm |
FDD100-IDE/300 | 300 mm |
FDD100-IDE/400 | 400 mm |
FDD100-IDE/500 | 500 mm |
FDD-IDE insulating roof elements for FDD with adhesive flange and FDD with foil flange.
Flat roof entry FDD-IDE, insulating roof element, thermally insulated, non-flammable (A1),
DN 160 for max. insulation thickness 200 / 300 / 400 mm, can be shortened individually to 80 mm.
Variants | max. insulation thickness |
FDD160-IDE/200 | 200 mm |
FDD160-IDE/300 | 300 mm |
FDD160-IDE/400 | 400 mm |
FDD160-IDE/500 | 500 mm |
Swan-neck entry for flat roofs SHDD assembled
Swan-neck entry for flat roofs SHDD. Available with 100, 150, 200 and 300 mm inside diameter
Swan-neck roof entry with welded connection plate. Dowel flange made as standard as adhesive flange in accordance with DIN 18533 120 mm circumferential for non-pressurised water in a flexible design incl. Drain hood, galvanized steel. Delivery is made assembled. Height and direction can also be changed, can be swivelled 360º.
Also available with fixed and loose flange designs in accordance with DIN 18533.
For shipping reasons, it may occur that the shipment is performed in 2 parts (lower part, upper part)
Special versions on request.
Variants | SHDD inside diameter |
SHDD100/assembled/VZ | 100 mm |
SHDD150/assembled/VZ | 150 mm |
SHDD200/assembled/VZ | 200 mm |
SHDD300/assembled/VZ | 300 mm |
Swan-neck entry for flat roofs SHDD, individual parts
Swan-neck entry for flat roofs SHDD. Available with 100, 150, 200 and 300 mm inside diameter
Swan-neck roof entry with welded connection plate. Dowel flange made as standard as adhesive flange in accordance with DIN 18533 120 mm circumferential for non-pressurised water in a flexible design incl. Drain hood. Hot-dip galvanized elements are assembled on site, resulting in cost-effective transport and easier installation on the roof. Height and direction can also be changed after assembly, can be swivelled 360º.
Also available with fixed and loose flange designs in accordance with DIN 18533.
Special versions on request.
Variants | SHDD inside diameter |
SHDD100/individual parts/VZ | 100 mm |
SHDD150/individual parts/VZ | 150 mm |
SHDD200/individual parts/VZ | 200 mm |
SHDD300/individual parts/VZ | 300 mm |
Multi flat roof entry MFD 50 with GPD
MFD 50/70 with GPD
Includes associated rubber press seal
GPD 68/1/ZxD for one or more cables .
Variants | Statement |
MFD-SF/50/GPD68/G/60 | SF = loose flange |
MFD-DB/50/GPD68/6/60 | DB = standard bitumen roofing sheet |
Multi flat roof entry MFD 125 with one connection piece
MFD125 with one connection piece and one thermal shrink sleeve.
Version for a cable with a diameter of 26 – 78 mm .
Variants | Statement |
MFD-SF/125/D1/80 | SF = loose flange |
MFD-DP/125/D1/80 | DB = standard bitumen sheet |
Multi flat roof entry MFD 125 with three connection pieces
MFD125 with three connection pieces and three thermal shrink sleeves.
Suitable for three cables with diameter 16–44 mm.
Various AK spreader caps or VS46 sealing plugs are available as accessories.
Variants |
Statement
|
MFD-SF/125/D3/46 | SF = loose flange |
MFD-DB/125/D3/46 | DB = standard bitumen roofing sheet |
Multi flat roof entry MFD 125 with seven connection pieces
One connection piece is supplied closed and can be opened if necessary.
Suitable for max. four cables with a diameter of 7-23 mm and max. four cables with a diameter of 7-30 mm.
Various AK spreader caps or VS25 or VS32 sealing plugs are available as accessories.
Variants | Statement |
MFD-SF/125/D7/32/25 | SF = loose flange |
MFD-DB/125/D7/32/25 | DB = standard bitumen roofing sheet |
Multi flat roof entry MFD 160 with one connection piece
MFD160 with one connection piece and one thermal shrink sleeve.
Version for a cable with a diameter of 34 – 108 mm.
Variants | Statement |
MFD-SF/160/D1/110 | SF = loose flange |
MFD-DB/160/D1/110 | DB = standard bitumen roofing sheet |
Version for a cable with a diameter of 26-78 mm.
Variants | Statement |
MFD-SF/160/D1/80 | SF = loose flange |
MFD-DB/160/D1/80 | DB = standard bitumen roofing sheet |
Multi flat roof entry MFD 160 with three connection pieces
MFD160 with three connection pieces and three thermal shrink sleeves.
Suitable for three cables with diameter 22 – 57 mm.
Various AK spreader caps or VS60 sealing plugs are available as accessories.
Variants | Statement |
MFD-SF/160/D3/59 | SF = loose flange |
MFD-DB/160/D3/59 | DB = standard bitumen roofing sheet |
Multi flat roof entry MFD 160 with eight conncetion pieces
MFD160 with eight connection pieces and four thermal shrink sleeves.
Four connection pieces are supplied closed and can be opened if necessary.
Suitable for max. four cables with a diameter of 7-23 mm and max. four cables with a diameter of 7-33 mm.
Various AK spreader caps or VS25 or VS35 sealing plugs are available as accessories.
Variants | Statement |
MFD-SF/160/D8/35/25 | SF = loose flange |
MFD-DB/160/D8/35/25 | DB = standard bitumen roofing sheet |
Multi flat roof entry MFD 125 with GPD 150/WE
MFD125 with GPD150/WE.
Multi flat roof entry with rubber press seal GPD150/G/60/WE110/V2A/EPDM ZxD, for one or more cables.
Variants | Statement |
MFD-DB/125/GPD150/WE | DB = standard bitumen roofing sheet |
Multi flat roof entry MFD 125 with GPD 150/WE
MFD125 with GPD150/WE.
Multi flat roof entry with rubber press seal GPD150/G/60/WE110/V2A/EPDM ZxD, for one or more cables.
Variants | Statement |
MFD-SF/125/GPD150/WE | SF = loose flange |
Multi flat roof entry MFD 160 with GPD 150 (WE)
MFD160 with GPD150
Multi flat roof entry with rubber press seal GPD150/G/60/V2A/EPDM 1xD, for one pipe or cable.
Variants | Statement |
MFD-DB/160/GPD150 | DB = standard bitumen roofing sheet |
MFD160 with GPD150/WE.
Multi flat roof entry with rubber press seal GPD150/G/60/WE110/V2A/EPDM ZxD,
with exchangeable insert for one or more cables.
Variants | Statement |
MFD-DB/160/GPD150/WE | DB = standard bitumen roofing sheet |
Multi flat roof entry MFD 160 with GPD 150/WE
MFD160 with GPD150/WE.
Multi flat roof entry with rubber press seal GPD150/G/60/WE110/V2A/EPDM ZxD, for one or more cables.
Variants | Statement |
MFD-SF/160/GPD150/WE | SF = loose flange |
Multi gabled roof entry MSD 110
Multiple gabled roof entry MSD 110,
available to match almost all roof coverings: Corrugated sheet, slate, plain roof tiles crown roof tiles, interlocking roof tiles and others.
With system cover and thermal shrink sleeve(s) for sealing cables or pipes. Also available as GPD with exchangeable insert.
Area of application: | Sloping roofs from 15° to 45°. |
Advantages: |
|
Sealing: | 2 bar |
Required information: | Roof tile shape, colour and manufacturer |
Variants | Sealing of cables and pipes |
MSD110/D1/75 | Connection cover with one connection piece and one thermal shrink sleeve for a cable with a diameter of 26 – 73 mm. |
MSD110/D1/80 | Connection cover with one connection piece and one thermal shrink sleeve for a cable with a diameter of 26 – 78 mm. |
MSD110/D3/30 | Connection cover with three connection pieces and three thermal shrink sleeves for cables with diameters of 7 – 28 mm. Various AK spreader caps or VS30 sealing plugs are available as accessories. |
MSD110/D3/46 | Connection cover with three connection pieces and three thermal shrink sleeves for cables with diameters of 16 - 44 mm. Various AK spreader caps or VS46 sealing plugs are available as accessories. |
MSD110/D5/20 | Connection cover with five connection pieces and five thermal shrink sleeves for cables with diameters of 7 - 18 mm. Various AK spreader caps or VS20 sealing plugs are available as accessories. |
MSD110/D7/32/25 | Connection cover with seven connection pieces and four thermal shrink sleeves for cables with diameters of 7-23 mm and three cables with diameters of 7-30 mm. One connection pieces is supplied closed, this can be openend if neccessary. Various AK spreader caps or VS25/VS32 sealing plugs are available as accessories. |
MSD110/GPD150/G/60//WE110/V2A/EPDM | Includes split rubber press seal with exchangeable insert Ø 110 mm. For a maximum of 12 x 1/2“ (16 mm) and 6 x RG8 cables (11 mm). |
Multi gabled roof entry MSD-Universal 125
Multiple gabled roof entry MSD-Universal 125,
available to match almost all roof coverings: Corrugated sheet, slate, plain roof tiles crown roof tiles, interlocking roof tiles and others.
With system cover and thermal shrink sleeve(s) for sealing cables or pipes. Also available as GPD with exchangeable insert.
Area of application: | Sloping roofs from 15° to 45°. |
Advantages: |
|
Sealing: | 2 bar |
Required information: | colour |
Variants | Sealing of cables and pipes |
MSD-Universal/125/D1/80 | Connection cover with one connection piece and one thermal shrink sleeve for a cable with a diameter of 26 – 78 mm. |
MSD-Universal/125/D3/46 | Connection cover with three connection pieces and three thermal shrink sleeves for cables with diameters of 16 - 44 mm. Various AK spreader caps or VS46 sealing plugs are available as accessories. |
MSD-Universal/125/D7/32/25 | Connection cover with seven connection pieces and four thermal shrink sleeves for cables with diameters of 7-23 mm and three cables with diameters of 7-30 mm. One connection pieces is supplied closed, this can be openend if neccessary. Various AK spreader caps or VS25/VS32 sealing plugs are available as accessories. |
MSD-Universal/125/GPD150/G/60//WE110/V2A/EPDM | Rubber press seal 150 GPD150/G/60/WE110/V2A/EPDM with exchangeable insert DN 110 mm 12 x 16 mm (1/2" cable) 6 x 11 mm (RG8 cable) Standard cable distribution for telecommunications and mobile communications |
Metal sheet entry TDD
Technology on the roofs of houses, halls or industrial plants is becoming increasingly important.
For the most part, photovoltaic systems are installed on inexpensive trapezoidal sheet roofs.
From the roof, the cables must be routed into the building by the shortest route.
We are following this trend with our roof entries, in particular with the new roof entry for trapezoidal sheet metal roofs.
Suitable for common bolt circle saw diameters 86 mm, 102 mm, 127 mm and 152 mm.
Variants | Opening diameter | F (see above) | Maximum configuration |
TDD86/60/F/WE/V2A/EPDM (Z)x(D) |
86 mm | 106 mm | e.g. 9 cables up to 8 mm |
TDD102/60/F/WE/V2A/EPDM (Z)x(D) |
102 mm | 122 mm | e.g. 16 cables up to 8 mm |
TDD127/60/F/WE/V2A/EPDM (Z)x(D) |
127 mm | 147 mm | e.g. 25 cables up to 8 mm |
TDD152/60/F/WE/V2A/EPDM (Z)x(D) |
152 mm | 172 mm | e.g. 40 cables up to 8 mm |